Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Tested with firmware (SCE_1-12-0-12-25224). Ask 2N for this firmware or  access to test web server - contact your salesman or send a request go to https://support.2n.cz

 

Connect you 2N® SmartCom PRO unit to your 2N® SmartCom server. In this scenario will be used 2N® SmartCom test server with web interface.

Check, that your unit is connected to the server. (Web interface or in software 2N® Control panel)

Image Removed

Image Added

Enable AMS function (0 = AMS turned off)

at^scams="enable",1                                                     

Meter detection:

Performing this command deletes all the data from 2N®SmartCom PRO terminal memory as well as the meter reading configuration part. The parameter interval is global for all installed meter meters by AT command.

AT command:
at^scamsadd=<port>,<protocol>,<baudrate>,<interval>,<number_of_expected_devices>

...

Go to web interface to section "Terminals Monitoring" and synchronize your 2N® SmartCom PRO unit with 2N® SmartCom server.

Image RemovedImage Removed

Pres Image Added

 

Press Start sync

Image RemovedImage Added

 

 

Wait until synchronization is finished

Image RemovedImage Added

 

 

In section "Meters" you can find information about your M-Bus meters

Image RemovedImage Added

 

 

Results are in section - "Results" - For the access data (login, password) please contact your salesman or send a request go to https://support.2n.cz

Image RemovedImage Added

Image Added

 

or can be download by FTP client - loggin name: o2 pass:o2ask 2N

Image Removed

 

Image Added


Anchor
Error
Error

Excerpt Include
test General AMS errorstest
General AMS errors

Excerpt Include
test M-Bus AMS errorstest
M-Bus AMS errors