- AXIS A9188 communicates with lift I/O Relay Module using its relays wired to lift system
- 2N devices communicate with AXIS A9188 via IP protocol HTTPS
- Time for relays open/close time is set by 2N devices to 10s (could be changed) which directly corresponds with time person have after his/her authorization on 2N device to push floor button in the lift
- One 2N device can connect to up to 5 8 AXIS A9188 I/O Relay Modules
- Multiple 2N devices are not recommended to connect to same AXIS A9188 I/O Relay Module
|