Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: IP Force 555v5 steps

...

Factory Default Resetting (PCB version 555v3 and higher)555v5)

 Press the RESET button.

  1. Wait until the red and green LEDs on the device come on simultaneously (approx. 20 s).
  2. Wait until the red LED goes off (approx. 5 s).
  3. Wait until the green LED goes off and the red LED comes on again (approx. 5 s).
  4. Wait until the red LED goes off (another 5 s).
  5. Release the RESET button.

Image Added

Figure: 2N® IP Force LED2 checking, PCB Version 555v5 


Factory Default Resetting (PCB version 555v3 )

For resetting device to default settings press and hold SW1 button and check LED2 state. After green LED2 turns off release SW1 after 5 - 10 seconds. If you hear the first sound signalization it is too late and nothing is changed. If you press the button for short time device will reboot only. SW1button is available in devices with PCB version 555v3 and higher. For devices with PCB version555v2 see procedure below.

                  

Image Removed

Figure: 2N® IP Force LED2 checking, PCB Version 555v5 


Factory Default Resetting (PCB version 555v2)

  1. Disconnect the device from the power supply.
  2. Move the short-circuit jumper on connector X6 into the Default setup position. Configuration jumpers (X6) are located in the right-hand upper corner of the PCB.
  3. Reconnect the power supply and wait for astartsignallingsound.
  4. Disconnect the device from the power supply.
  5. Move the short-circuit jumper on connector X6 into the Normal operation position.
  6. Reconnect the power supply. The device will be reset to factory default.

...