This FAQ describes how to connect external LED diode, alarm light  to the 2N® Indoor Touch 2.0 and how to configure 2N® Helios 2N® IP Mobile (Intercoms) application. With relay it is possible to connect external ringing notification that is powered from the 2N® Indoor Touch 2.0. 

Function external ringing notification ON/OFF  activates external notification thanks to relay 1, 2. Activate relays is possible either by bell button or incoming call.

 

Info
titleRequirement
  • 2N® Indoor Touch with firmware 2.0 or higher
  • 2N® Helios 2N® IP Mobile ver. 4.2 or higher(Intercoms)
  • Accessories for Relay
  • 2-wires cables

How to connect bell button to the 2N® Indoor Touch

 2N® Indoor Touch contains, on the opposite site, ports to connect 3rd party devices to the relay and control them from application. As you can see in pictures (1, 2), there are relay1, relay2. 

                        Image Removed              Image RemovedImage Added

Pic.1, 2

 

How to connect

external ringing notification and

bell button to 2N® Indoor Touch:

Connect 2-wires bell button to the 2N® Indoor Touch. Use ports IN1 or IN2, DC12V+ OUT. In the picture (3) is shown IN1, DC12V+ OUT.    

              

Image Removed

Image Added

Pic.
3
2

How to connect external ringing notification to 2N® Indoor Touch:

  Connect 2-wires external LED diode to the  2N® Indoor Touch 2.0 . Use ports  DC12V+ OUT, Relay1, Relay2, GND . In the picture (4) is shown DC12V+ OUT, Relay1, GND.  
                                                                                           
Image Removed
Image Added
Pic.
4
3
 

How to connect external ringing notification and door bell button to 2N® Indoor Touch:

In pictures (5, 6) there are 2-wires bell button and relay connected together. LED diode is powered from the  2N® Indoor Touch 2.

                                               Image Removed          

0.

 

Image AddedImage Modified


Pic.

5, 6

4

 

In

pictures (7, 8)

picture 5 there are 2-wires bell button and relay connection. External bell as external ringing notification is powered from the external power source.


                                               Image Modified         Image Modified

Pic.

7, 8

5

How to configure 2N®

Helios IP Mobile ver. 4.2

IP Mobile (Intercoms) for bell button:

Open 2N®

Helios

IP Mobile (Intercoms), go to Settings and turn on the Door button

Image AddedImage Added

                                                                                                                             

  Image Removed                                                                                                                              Pic.9

Pic.6

Select the desired input for the door bell button. In our case we have to set up the interface for GPI1.

Image Removed


Image Added
                                                                                                                                Pic.

10

7

Inverted/ Non-inverted Input – In this section it is possible to change the logic of the button. GPI1,2 are by default in logical 1

Non-inverted Input  – The application is not ringing once the button is pressed. Once you release the button the application starts to ring. The time for ringing is defined in section Maximal ringing time.

Inverted Input – Application is ringing during the time you are holding the button. If you only press the button, the application will be ringing minimal ringing time. You can set up the value of the minimal ringing time in the application- Section Minimal ringing time.

Image Modified

               Image Removed             Image RemovedImage Added

  Pic.

11

8

 How to setup external ringing notification in 2N®

Helios IP Mobile ver. 4.2

IP Mobile (Intercoms)

  1. For relay is the external ringing notification section (12, 13)section 
        Image Removed         Image RemovedImage Added
                                                                                                                                Pic.12, 139

    • Inverted relay output O – Relay (external notification) works as normally open contact.
    • Inverted relay output OFF – Relay (external notification) works as normally close contact.
  2. Select the desired relay for the 2N® Indoor Touch. In our case we have to setup the interface for Relay1
                                                   Image RemovedImage Added
                                                                                                                                    Pic.1410
Info
titleManual

For more information please follow the user guide here: https://wiki.2n.cz/pages/viewpage.action?pageId=43292405

Call Log

  • Call Log (1511) saves all calls done by bell button

     .

   Pic.1511