Cloak
You are able to mount the tamper switch to the 2N® IP Verso with usage of I/O (9155034) or Wiegand module (9155037) in order to be used via Automation.
It could be also installed alone and wired directly to the security control panel.

With I/O module

 

 

In order to control events of the temper switch in the Automation (Event - “InputChanged”) the input Tamper is addressed as follows: <module_name>.<tamper>, e.g. module2.tamper.

 



50%

I/O module with Tamper switch contacts

50%

Tamper switch mounting


With Wiegand module

 

 

In order to control events of the temper switch in the Automation the input Tamper is addressed as follows: <module_name>.<tamper>, e.g. module2.tamper.

 



50%

Wiegand module with Tamper switch contacts

50%

Tamper switch mounting

Standalone

The switch leads directly to the terminal board and is designed for connection to an external security exchange (32 V DC / 50 mA max).

This module is not connected to the bus.

 

 

...